Black Box Switch KVT128AE UK 16 R2 User Manual

ServView 17S  
KVM Switch  
Quick Start Guide  
KVT128AE-UK-8-R2  
KVT128AE-UK-16-R2  
 
ServView 17S KVM Switch Quick Start Guide  
1.1 Important Safeguards  
Please read all of these instructions carefully before you use the device. Save this  
manual for future reference.  
What the warranty does NOT cover  
Any product, on which the serial number has been defaced, modified or removed.  
Damage, deterioration or malfunction resulting from:  
Accident, misuse, neglect, fire, water, lightning, or other acts of nature, unauthorised  
product modification, or failure to follow instructions supplied with the product.  
Repair or attempted repair by anyone not authorised by us.  
Any damage of the product due to shipment.  
Removal or installation of the product.  
Causes external to the product, such as electric power fluctuation or failure.  
Use of supplies or parts not meeting our specifications.  
Normal wear and tear.  
Any other causes which does not relate to a product defect.  
1.2 Regulatory Notice  
Legal Information  
Information in this document has been carefully checked for accuracy; however, no  
guarantee is given to the correctness of the contents. The information in this document is  
subject to change without notice. We are not liable for any injury or loss that results from  
the use of this equipment.  
Safety Instructions  
Unplug equipment before cleaning. Don’t use liquid or spray detergent; use a moist  
cloth.  
Keep equipment away from excessive humidity and heat. Preferably, keep it in an air-  
conditioned environment with temperatures not exceeding 40º Celsius (104º Fahrenheit).  
When installing, place the equipment on a sturdy, level surface to prevent it from  
accidentally falling and causing damage to other equipment or injury to persons nearby.  
When the drawer is in an open position, do not cover, block or in any way obstruct the  
gap between it and the power supply. Proper air convection is necessary to keep it from  
overheating.  
Arrange the equipment’s power cord in such a way that others won’t trip or fall over it.  
If you are using a power cord that didn’t ship with the equipment, ensure that it is rated  
for the voltage and current labeled on the equipment’s electrical ratings label. The  
voltage rating on the cord should be higher than the one listed on the equipment’s  
ratings label.  
Observe all precautions and warnings attached to the equipment.  
If you don’t intend on using the equipment for a long time, disconnect it from the power  
outlet to prevent being damaged by transient over-voltage.  
1
 
ServView 17S KVM Switch Quick Start Guide  
Keep all liquids away from the equipment to minimize the risk of accidental spillage.  
Liquid spilled on to the power supply or on other hardware may cause damage, fire or  
electrical shock.  
Only qualified service personnel should open the chassis. Opening it yourself could  
damage the equipment and invalidate its warranty.  
If any part of the equipment becomes damaged or stops functioning, have it checked by  
qualified service personnel.  
Regulatory Notices Federal Communications Commission (FCC)  
This equipment has been tested and found to comply with the limits for a Class B digital  
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable  
protection against harmful interference in a residential installation. Any changes or  
modifications made to this equipment may void the user’s authority to operate this  
equipment. This equipment generates, uses, and can radiate radio frequency energy and, if  
not installed and used in accordance with the instructions, may cause harmful interference to  
radio communications. However, there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful interference to radio or  
television reception, which can be determined by turning the equipment off and on, the user  
is encouraged to try to correct the interference by one or more of the following measures:  
Re-position or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the  
receiver is connected.  
1.3 Before Installation  
It is very important to locate the KVM in a suitable environment.  
The surface for locating and fixing the KVM switch should be stable and level or mounted  
into a suitable cabinet.  
Make sure the place has good ventilation, is out of direct sunlight and away from sources  
of excessive dust, dirt, heat, water, moisture and vibration.  
Position LCD Keyboard Drawer with respect to related facilities.  
2
 
ServView 17S KVM Switch Quick Start Guide  
2.1 Password  
The password is disabled by default (i.e. There is no password required when you power on  
the KVM switch for the first time)  
Enable password.  
1.  
2.  
3.  
Enter the KVM hotkey Scroll Lock + Scroll Lock + U  
Logout of the KVM switch by entering the hotkey Scroll Lock + Scroll Lock + P  
In SUPERVISOR level, enter “00000000” eight zeros in the user name & password field  
(Do not use the “0” on the number pad)  
4.  
In USER level, enter Space bar + Enter in the user name & password field  
Note: Automatic logout after 10 minutes of inactivity  
Set your own user name & password.  
1.  
Login to the KVM switch in SUPERVISOR level by entering “00000000” eight zeros in user name &  
password field.  
2.  
3.  
4.  
5.  
Call the KVM OSD menu by entering the KVM hotkey Scroll Lock + Scroll Lock + Space Bar.  
Enter F1 to view the MAIN MENU.  
Select “USER SECURITY”.  
Set password in SUPERVISOR & USER level.  
a. In the top-left row “S” (SUPERVISOR), press Enter to set your own user name & password.  
b. In the row 1 to 8 (USER), press Enter to set your own user name & password.  
Press Enter to save the settings or press Esc to cancel without saving.  
Note: a. Blank has an underscore, while SPACE does not.  
6.  
b. Enter any alphanumeric key to move to next input item. SPACE is treated as a valid character.  
Change your password.  
1.  
2.  
3.  
4.  
5.  
Login to the KVM switch in SUPERVISOR level by entering your own user name & password.  
Call the KVM OSD menu by entering the KVM hotkey Scroll Lock + Scroll Lock + Space Bar.  
Press F1 to view the MAIN MENU.  
Select “USER SECURITY”.  
Change the password in SUPERVISOR & USER level.  
a. In the top-left row “S” (SUPERVISOR), press Enter to change your user name & password.  
b. In the row 1 to 8 (USER), press Enter to change your user name & password.  
Press Enter to save the setting or press Esc to cancel without saving.  
Note: a. Blank has underscore, while SPACE does not.  
6.  
b. Enter any alphanumeric key to move to next input item. SPACE is treated as a valid  
character.  
Enable password.  
1.  
2.  
3.  
Enter the KVM hotkey Scroll Lock + Scroll Lock + U.  
Logout of the KVM switch by entering the KVM hotkey Scroll Lock + Scroll Lock + P.  
Following this you will not need a user name & password to access the KVM OSD menu.  
Forget your password.  
1.  
Please contact Black Box for further support.  
Note:  
You must enter the KVM hotkey within 2 seconds.  
A beep sound will be heard once you have successfully entered the hotkey.  
3
 
ServView 17S KVM Switch Quick Start Guide  
2.2 KVM OSD  
OSD Menu  
OSD operation  
next to the system name  
next to the system name  
The PC is powered on  
The PC is selected  
F1  
Access F1 MAIN MENU  
Logout the OSD menu  
Previous menu  
F2  
F3  
Esc  
Enter  
Cancel/Quit  
Complete/Switch to selected port  
Switch to previous or next port  
PageUp/PageDown  
1/2/3/4  
SWitch to previous bank or next bank  
Display port 01-08/09-16/17-24/25-32  
Note: Display port 17-32 for 32 port model only  
F1 Main Menu  
4
 
ServView 17S KVM Switch Quick Start Guide  
01  
02  
03  
04  
05  
06  
07  
LANGUAGE  
OSD language change  
PORT NAME EDIT  
PORT SEARCH  
USER SECURITY  
ACCESS LIST  
HOTKEY  
Define port name  
Quick searching by port name  
Change password  
Define user access authority  
Change hotkey  
TIME SETTINGS  
Modify scan display time interval  
08  
OSD MOUSE  
Modify OSD mouse speed  
5
 
ServView 17S KVM Switch Quick Start Guide  
2.3 KVM Hotkey  
Local Console Hotkey  
Hotkey  
Function  
Calling OSD menu  
Calling OSD menu  
Switch to previous port  
Switch to next port  
Scroll Lock + Scroll Lock + Space Bar  
Right-button mouse + Esc  
Scroll Lock + Scroll Lock +  
Scroll Lock + Scroll Lock +  
Switch to previous bank or next bank  
Switch to specific port  
Scroll Lock + Scroll Lock + PgUp/PgDown  
Scroll Lock + Scroll Lock + Bank no. + Port no.  
Turn the buzzer ON and OFF  
* Default the buzzer is ON  
Scroll Lock + Scroll Lock + B  
Logout the KVM if password security is ON. Show  
up the status windows.  
Scroll Lock + Scroll Lock + P  
Adavanced hotkeys (for Supervisor login only)  
Activate auto-scan mode for connected servers  
* Enter any key to exit the auto-scan mode  
Scroll Lock + Scroll Lock + S  
Scroll Lock + Scroll Lock + R  
Scroll Lock + Scroll Lock + U  
Reset all the KVM settings to factory default  
*Except User Security settings  
Disable and enable password security  
* Default security is OFF  
To enable/disable the screen saving function and 10  
minutes auto-logout  
Scroll Lock + Scroll Lock + L  
Example:  
Scroll Lock + Scroll Lock + Bank no. + Port no.”  
- Bank no. : 1 to 8  
- Port no. : 01 to 16  
.
- e.g. Bank 1 Port 4: Scroll Lock + Scroll Lock + 1 + 0 + 4  
- e.g. Bank 2 Port 16: Scroll Lock + Scroll Lock + 2 + 1 + 6  
You must enter the hotkey within 2 seconds.  
A beep sound will be heard once the hotkey had been successfully entered.  
The numerical keypad is not supported by the OSD. The arrow keys, PgUp, PgDn, and  
Enter keys are supported.  
6
 
ServView 17S KVM Switch Quick Start Guide  
Remote Console Hotkey  
Hotkey  
Function  
Calls the Help OSD windows  
Select Hotkey *Default is Caps Lock  
Toggle the switch between remote & local port  
Caps Lock + Caps Lock + F1  
Caps Lock + Caps Lock + F2  
Caps Lock + Caps Lock + C  
Turn the buzzer ON & OFF  
* By default the buzzer is ON  
Caps Lock + Caps Lock + Q  
Activate auto-scan mode for remote & local port  
* The scan time interval is 5 seconds  
Caps Lock + Caps Lock + S  
Caps Lock + Caps Lock + A  
Auto-adjust the video signal  
7
 
Customer Support Information:  
FREE tech support 24 hours a day, 7 days a week: Call 0118 965 6000  
Address: Black Box Network Services (UK) Ltd., 464 Basingstoke Road, Reading, Berkshire, RG2 0BG  
Web:www.blackbox.co.uk E-mail: info@blackbox.co.uk  
© Copyright 2007. Black Box Corporation. All rights reserved.  
 

Black Decker Network Card CA JLTDHK User Manual
Blanco Indoor Furnishings 157 092 User Manual
Blaupunkt Car Stereo System CR127 User Manual
BodyCraft Home Gym F412 User Manual
BodyCraft Home Gym F660 User Manual
Bosch Appliances Automobile Accessories SM515 User Manual
Broan Ventilation Hood QTR050 User Manual
Brother Fax Machine DCP 770CW User Manual
Capcom Video Games 13388330461 User Manual
Chicago Electric Welder 95424 User Manual