Since 1911
ESP Espresso Machines
Instruction Manual
Models: ESP1, ESP2 and ESP3
Cecilware Corporation 43-05 20th. Avenue, LIC NY 11105
Tel: 800.935.2211 / 718.932.1414 • Fax: 718.932.7860
®
Since 1911
NR27A (05/08)
www.cecilware.com
1 General
1-1
1-2
This operations manual includes instructions for using and maintaining your espresso
machine, please keep this manual readily available.
After unpacking, please check to ensure your machine has not been damaged during
shipping and includes all parts/components. Please notify your service representative
regarding any questions or concerns before installing. Please note that machine
packaging material can be dangerous and should be kept out of reach of children.
1-3
Please confirm that your electricity supply conforms to the espresso machine power
requirements. A qualified technician should install the machine in accordance with
manufacturer instructions. The manufacturer assumes no responsibility for injury or
damage resulting from improper installation.
1-4
1-5
Please use an independent and suitable power source for your machine.
Please use an independent, fuseless breaker appropriate to machine safety requirements.
Do not plug your machine into an extension cord.
1-6
1-7
Be sure to use a grounded power source to prevent electric shock and ensure operating
safety.
Use the automatic espresso machine for its intended purpose only. Any other usage is
inappropriate and may be dangerous. The manufacturer assumes no responsibility for
injury, loss or damage resulting from improper machine use.
1-8
Do Not:
a. touch machine with wet hands or feet.
b. touch machine with bare feet.
c. pull on the cord to disconnect machine from power outlet.
d. expose the espresso machine to rain or direct sunlight.
e. permit children or persons not normally qualified to operate basic machinery to use
this machine.
1-9
Turn off the power source first before maintaining or servicing your espresso machine.
1-10 Take care when touching machine parts; subject to high temperature heating to avoid
injury.
1-11 Clean machine according to instructions provided in this manual to ensure proper
operations.
1-12 Turn power off if machine functions abnormally and notify qualified service personnel for
repairs. Do not permit non-qualified service personnel to attempt repairs. Continuing to
use a damaged or otherwise irregularly functioning machine will nullify the manufacturer
warranty.
3
1-13 Use softened water to make coffee or tea. Well / municipal water should be softened to
prevent scaling in the boiler, which will shorten the serviceable life of your machine. If a
hard water source is used, the filter should be replaced every two weeks -- although
long-life filters may remain serviceable up to eight weeks. Actual filter replacement
scheduling will vary based on volume and quality of water used.
1-14 The machine refills water automatically (see Section 4-2 for initializing). An error code will
appear if water flow into the machine exceeds two minutes (see Troubleshooting Section
in this manual), and power will be cut off automatically to protect the system. To resume
normal functions, restart the system after three or more seconds.
1-15 The heating element will not operate when water in the machine is less than the minimum
required level. When starting the machine without any water in the tank, heating will be
delayed for about 60 seconds.
1-16 Please ensure the water inside the piping will not be frozen while using the machine. The
water temperature must maintain over the freezing point even during the power off
period. The warranty does not cover any damages on piping and boiler cost by frozen
water.
1-17 When turning off the machine for long-term, please be sure to evacuate the water inside
the piping completely. For this may freeze the water and lead to damaging the machine.
To ensure the safety of your machine, please notify your service representative regarding
any needs on operations in frigid zone or prepare to shut down the machine for long-term
for complete water evacuation.
2. Operating Precautions
!
!
Do not use the machine and turn off the power when water intake has ceased.
When operating the machine for the first time or replacing the filter, remove the water inlet
tube and allow it to drain for about one minute in order to discharge impurities from the
water.
!
!
Please check and confirm normal water supply before turning on power.
Please check and confirm water level registers within the green zone. Operating the
machine outside the green zone may cause the electric heating element to overheat and
burn out.
!
!
After installing the machine, please check to make sure that, during water intake, the
steam pressure gauge indicator is within the green zone (1~1.4bar) and the water
pressure gauge indicator is also within the green zone (8~10bar). Please adjust the
system to the water supply pressure conditions in your area.
The water and steam taps are used to make coffee or tea. The nozzle at the hot water
outlet and the steam outlet are very hot -- please do not touch.
4
To avoid overheating, electric wires should be kept untangled and free of obstructions.
Do not block air intake or outlet vents on the machine. Never cover or otherwise prevent
the free flow of air across the cup warmer.
!
!
!
!
Please clean machine components with a soft cloth only. Do not use plastic or wire
brushes.
Turn the power off and release all boiler pressure if the machine is to remain idle for an
extended period of time.
Place an appropriate quantity of ground coffee in the filter cup and tamper carefully.
Clean all residual coffee from the rim and sides of the filter to ensure a good seal and full
pressure for steaming and to maximize service life.
!
!
!
The filter basket must be connected firmly to the filter support during steaming to avoid
disengagement of the handle or overflow.
Remove the cup from the steam tube after foaming milk. Failure to do so may draw
liquid from the cup into the steam tube, risking machine component contamination.
After machine power has been switched off, always let the machine set for at least 3
seconds before restarting.
3. Machine Overview
A. Foot
B. Water tray
I. Manual water outlet controller
J. Power indicator
C. Pressure gauge (water/steam pressure)
K. Power switch
D. Steam tube
L. Water level viewing window
M. Manufacturer plate
N. Filter basket handle
O. Cup warming tray holder
E. Hot water outlet nozzle
F. Hot water control knob
G. Steam control knob
H. Control Panel
5
4. Operations
4-1 Activating / Deactivating the Water Inlet Motor
a. If filtered water source pressure exceeds 2 bar and the amount of hot water needed is
small, turn the water inlet motor (2) to the OFF (up) position to permit water inflow
without internal pump assistance.
b. In areas of low source water pressure, turn the water inlet motor (2) to the ON (down)
position to activate the internal pump and draw water into the boiler mechanically.
Caution: When source water pressure is low & turn the water inlet
motor (2) to the OFF (up) position may risks drawing hot water away
from the boiler and damaging the pump and water intake solenoid.
4-2
Starting the Automatic Machine
a. Check and confirm that water source is in normal working order.
b. Turn the power switch to position 1 to initiate automatic system check. If boiler water
level is not in the green zone, wait until the automatic water replenishment process is
complete before proceeding to the next step.
c. Heating will stop when boiler pressure reaches approximately 1.2 bars (factory default
setting). Do not operate machine until steam pressure gauge reading is in the green
zone.
4-3
Using the Various Machine Functions
a. Steam Output
Turn steam knob counterclockwise to draw steam through the steam tube. Steam
output will increase the further the steam knob is turned. Turn the knob clockwise to
reduce/stop steam output. Pull out the steam knob when needing a good deal of
steam for a short period of time.
b. Hot Water Output
Turn the hot water knob counterclockwise to obtain hot water through the hot water
tube. Hot water output will increase the further the hot water knob is turned. Turn the
knob clockwise to reduce/stop steam output. Pull out the hot water knob for hot water
supply for a short period of time.
6
c. Coffee / Tea Output Presets
Place an appropriate quantity of ground coffee or tea in the filter basket and fix it into
the handle seat. Choose desired water output by selecting coffee or tea output values
1 through 4. Coffee or tea flow will stop automatically.
d. Continuous Output & Stop
Place an appropriate quantity of ground coffee or tea into the filter basket, and fix it
into the handle seat. Press the manual output button to start coffee or tea flow. Press
once again to stop.
4-4
Output Volume, Estimated steep time, and Frequency Setup
There are two identical button suites on two-cup models and three identical button
suites on 3-cup models. No default coffee / tea output setting is provided. Settings
must be made manually during set-up. If you are using a multi-cup machine, settings
made on the farthest right hand side button suite will serve as the default for the others.
Therefore, to set different values for different cup compartments, begin set up from the
right and work your way to the left, to prevent the previous setting been covered.
Manual Output Button
Control Panel
7
Output Volume Setup
a. Turn the output volume setup switch ON (1) and press the PROG (setup) button.
LED
Setup Button
Output Keys
b. The output LEDs should be lit, indicating the machine is in setup mode.
c. To configure key 1, press the key 1 button, which should light LED 1 and switch off all
other LEDs. Once desired setup parameters have been set, press key 1 again to
confirm and exit key 1 setup.
d. At this point, LED 1 should be off and LED's 2, 3 and 4 should be lit.
e. Repeat steps (b) through (d) to set up keys 2, 3 and 4, respectively.
f. The left set(s) of keys will mirror the value settings in the set of keys to its immediate
right. Repeat steps (b) through (e) if different output volumes are desired for different
cup compartments.
g. After completing setup, turn the output volume setup switch OFF (1) to return the
machine to normal operational mode.
4-5
Automatic Reverse Flushing
a. Press any key simultaneously to start automatic reverse flushing. Keys 2-4 in the
control panel will start flashing and start automatic reverse flushing from the right
output system to the left.
b. The default is 10 cleaning cycles.
c. Flush the second output system after flushing the first output system. Or press the 3rd
key to skip to the next output system, System will stop automatically after finish all the
reverse flushing.
4-6
Stopping the Machine
a. After cleaning the machine, remove all liquids and solid matter from the water tray.
b. Turn off the power (turn power switch to position 0).
c. Open steam knob to release steam flow. Do not place any liquid under the steam tube
during this process in to avoid system contamination.
5. Cleaning and Maintenance
5-1 Cleaning the Machine Body
Wipe machine exterior with soft, slightly dampened cloth daily before starting operations.
8
If necessary, a mild, non-corrosive cleaning agent may be applied to the cloth. Do not
spray cleaning agents directly on the machine body to avoid corrosion and possible
damage to circuits.
5-2 Brewing System
After each brewing cycle, remove the handle and press the manual water output button to
remove all residual ground coffee from the filter element. Then, fix the handle to the seat
again (Important: Do not force handle or fix it into the seat too tightly). Press the manual
water output button, shake the handle to clean the handle seat gasket and remove
residual coffee grounds from the along the inside.
A Flush the steam outlet in REVERSE daily before shutting off the machine.
Remove the copper plate and filter element from the water outlet (be careful, metal
components may be hot).
B Place a reverse flushing silica plate in the filter cup, and apply about 2-3 grams of
detergent. Fix the handle into the seat and check for tightness.
C To dissolve residual detergent in the machine, press the manual water output button
for approximately 4 seconds and release. Repeat this process several times. Press
the manual water output button and shake the handle to clean the gasket and the
inside of the brewer. Continue the process until water in the filter cup is clear and
clean.
D After cleaning, remove the handle. Press the manual water output button to allow
residual cleaning solution in the brewing system to flow out. Turn water off after
flushing for about one minute.
a. During reverse flushing, remove and wash the copper plate and filter element with
clean tap water. Wipe with soft cloth.
b. If process is unable to sufficiently clean the plate and filter element, immerse the
components overnight in a mild cleaning solution of 3 tsp detergent in 1 pint hot water.
Rinse and reassemble components before restarting the espresso machine.
5-3
Filter Basket and Basket Handle
a. Rinse the handle with hot water after each brewing cycle to dissolve residual oils in the
filter basket and outlet nozzle and prevent oils from affecting the quality of coffee.
b. Disassemble filter basket handle and filter basket. Immerse both in cleaning solution
(3tsp of detergent in 1 pint hot water) for 24 hours to dissolve residual coffee oils.
Important: Do not immerse the plastic portion of the handle in the cleaning solution to
avoid deterioration.
C. Rinse all components with clean water. Wipe with a soft, clean cloth only.
9
Dia. Part
List
#
1
2
3
4
#
Description
Price
01346 SILICA GEL WASHER . . . . . . . . . . . . $ 2.10
01347 1 CUP FILTER HOLDER ASSY . . . . . 156.40
01348 1 CUP STAINLESS STEEL FILTER . .
01349 1 CUP FILTER HOLDER
24.60
WITHOUT FILTER . . . . . . . . . . . . . . . 121.20
5
6
7
8
9
01350 FILTER SUPPORT . . . . . . . . . . . . . . .
01351 BRASS SPOUT 1 LONG CUP . . . . . .
01352 FILTER CLAMP SPRING D1.4 . . . . . .
01353 FILTER HOLDER KNOB CAP . . . . . .
01354 FILTER HOLDER BACK LID . . . . . . .
83.70
23.40
1.00
14.00
1.50
10 01355 2 CUPS FILTER HOLDER ASSY . . . . 163.00
11 01356 2 CUPS STAINLESS STEEL FILTER .
12 01357 2 CUPS FILTER HOLDER
24.60
WITHOUT FILTER . . . . . . . . . . . . . . . 127.90
13 01358 2 CUPS BRASS SPOUT . . . . . . . . . . 30.00
5-4
5-5
Steam Tube
a. After making steamed milk, use a slightly moistened soft cloth to wipe steam tube.
After wiping, release a steam burst through the tube to remove any residual milk
remaining in the nozzle.
b. If hardened milk residuals remain in the steam tube, disassemble and immerse tube in
hot water for about 20 minutes to soften. Reassemble and repeat step (a).
Boiler
To extend your boiler’s serviceable life, when the machine is expected to sit idle for a
period of one or more days, turn power to the machine OFF and open the steam
output to discharge pressure in the boiler. Continue until the pressure gauge reading
falls to zero and steam discharge ends. Once complete, empty and clean the water
tray and discharge trough. (Important: Leave the steam output setting open following
steam discharge. Steam output should remain open until after the machine is turned
back on and hot water begins dripping from the steam tube.
5-6
5-7
Water Tray
Remove and wash the water tray after stopping your automatic machine. Reassemble
after the water tray has dried.
Discharge Trough
a. After removing the water tray, wipe and remove sediments in the discharge trough with
a wet cloth or napkin and wash with hot water to clear the discharge tube.
b. If water does not discharge properly, place a teaspoon of detergent into the discharge
trough and flush with hot water to dissolve residual oils in the tube.
5-8
Filter
a. The manufacturer recommends replacing the filter element on the resin exchange filter
after processing 53 gallons of water (about 3,000 – 4,000 cups of coffee). This
schedule can be expected to vary based on the quality of water used in your machine.
10
6 Trouble Shooting
Corrective
Actions
Indication
Status
Possible Cause
After two minutes of
1. Make sure that the water
input switch is ON and
that water is flowing into
the machine.
water input, indicator
still does not show a
rise in machine water
level. It will take more
than two minutes to
replenish water when
the machine is used
for the first time.
1. Water level indicator not
functioning properly.
2. Water intake solenoid is
L
out of order. Input water 2. Turn off the machine.
flow has been
interrupted.
Restart after 3 seconds.
3. Notify local dealer.
1. No water output from 1. Coffee grounds are too 1. Adjust coffee ground
the brewer.
2. Machine does not
reach preset
fine.
fineness.
2. Ensure water input is
normal.
E
2. No water input
3. Water intake solenoid is
out of order.
parameters.
3. Notify local dealer.
Boiler water level is too
low, automatic water
input system is working.
Boiler is in automatic
water input mode.
Indication of an action for
reference.
.
1. Turn machine off.Restart
after 3 seconds.
2. Notify local dealer.
IC board does not
function properly.
Software or hardware
error.
A or B
Wait at least 3 seconds to restart the automatic espresso machine after turning it off to ensure
previous data stored in machine memory is erased. Turning the machine on too quickly may
cause the machine to function improperly.
11
7. Replacement Parts (For Reference Only)
Item
1
Particular
Brewer gasket
Serviceable Life
3 - 6 months, depending of volume
of coffee brewed
2
3
4
5
6
7
8
Upper gasket for steam tube
Lower gasket for steam tube
Leak-stop gasket for steam/hot water valve
Upper gasket for steam/hot water valve
Pressure relief valve
1 year
1 year
1 year
1 year
2 years
2 years
Safety valve
Filter pad
1 – 3 months, depending on water
quality
9
Filter element (active carbon)
Filter element (soft water resin)
1 – 3 months, depending on water
quality
1 – 3 months, depending on water
quality
10
Overall Composition Chart ESP1, ESP2, ESP3
Dia. Part
List
Dia. Part
List
#
1
2
3
4
5
6
7
8
#
Description
Price
#
9
#
xxx
Description
Price
xxx
xxx
xxx
xxx
SCREW M4*8 . . . . . . . . . . . . . . . . . .
NUT M10 . . . . . . . . . . . . . . . . . . . . . .
SPRING WASHER M10 . . . . . . . . . . .
DRAIN BASIN . . . . . . . . . . . . . . . . . .
FLOWMETER DOSER ASSY . . . . . . .
NUT M6 . . . . . . . . . . . . . . . . . . . . . . .
SPRING WASHER M6 . . . . . . . . . . . .
ANTI FOOT VIBRATION . . . . . . . . . . .
10 xxx
11 xxx
12 xxx
01325 FLOWMETER DOSER . . . . . . . . . . . $161.50
13 01331 PRESSURE GAUGE FOR ESP 220V . $188.20
xxx
xxx
xxx
BRASS FITTING PS/1/4*PS1/4*L33.5
BRASS FITTING PS/1/4*PS1/4*L42 .
SCREW M4*6 . . . . . . . . . . . . . . . . . .
14 xxx
15. xxx
16. xxx
PRESSURE GAUGE . . . . . . . . . . . . .
SCREW M8*20
SPRING WASHER M8
xxx special order contact Cecilware for more information
12
Electrical Assembly
Dia. Part
List
Dia. Part
List
#
#
Description
Price
#
#
Description
Price
1
xxx
xxx
xxx
xxx
xxx
xxx
xxx
xxx
xxx
xxx
MAIN SWITCH ASSY ESP1 . . . . . . . .
MAIN SWITCH ASSY ESP2 . . . . . . . .
MAIN SWITCH ASSY ESP3 . . . . . . . .
MAIN SWITCH ESP1, 2 . . . . . . . . . . .
MAIN SWITCH ESP3 . . . . . . . . . . . . . .
CABLE UNIT ESP1 . . . . . . . . . . . . . . .
CABLE UNIT ESP2 . . . . . . . . . . . . . . .
CABLE UNIT ESP3 . . . . . . . . . . . . . . .
LUMINOUS BLACK BIPOLAR . . . . . .
GREEN INDICATOR LAMP . . . . . . . . .
xxx
SOLID STATE RELAY 50A
GN84137021 ESP2, ESP3 . . . . . . . . .
20 xxx
SINGLE CABLE
2
3
PRESSURE SWITCH<->PCB . . . . . .
MOTOR POWER ESP1,120V . . . . . . .
MOTOR POWER ESP1, 220V . . . . . . .
MOTOR POWER ESP2 . . . . . . . . . . . .
MOTOR POWER ESP3 . . . . . . . . . . . .
SSR-PRESSURE SWITCH CABLE . . .
FAN FOR SSR . . . . . . . . . . . . . . . . . .
RADIATOR . . . . . . . . . . . . . . . . . . . . .
MAIN SWITCH COVER . . . . . . . . . . . .
BAND . . . . . . . . . . . . . . . . . . . . . . . . .
MAIN SWITCH HAND GRIP LABEL PLATE
MAIN SWITCH HAND GRIP . . . . . . . .
SSR HOLDER . . . . . . . . . . . . . . . . . . .
21 xxx
xxx
xxx
xxx
4
5
6
22 xxx
23 xxx
24 xxx
25 xxx
26 xxx
27 xxx
28 xxx
29 xxx
01326 SI 501 CE PRESSURE SWITCH
110V / 240V AC 20A . . . . . . . . . . . . . $ 319.50
CONTROL BOX WITH IC BOARD . . . .
01328 CONTROL PC-MAIN BOARD . . . . . . . $ 400.40
7
8
9
xxx
xxx
xxx
FUSE 1.5A . . . . . . . . . . . . . . . . . . . . . .
FUSE 4A (MOTOR) . . . . . . . . . . . . . . .
SERIES CABLE PCB PANEL . . . . . . . .
SERIES CABLE PANEL . . . . . . . . . . . .
SELECT SWITCH . . . . . . . . . . . . . . . .
LEVEL PROBE CABLE . . . . . . . . . . . .
HEATING ELEMENT POWER CABLE .
FLOWMETER GAUGE CABLE ESP1 .
10 xxx
11 xxx
12 xxx
13 xxx
14 xxx
15 xxx
30 01338 TEMP. PROTECTION FUSE . . . . . . . .
$ 8.60
31 xxx
xxx
CONTROL BOX WITHOUT IC
BOARD (UP & DOWN COVER) . . . . . .
32 xxx
33 xxx
34 xxx
35 xxx
36 xxx
37 xxx
AS MANIPULATION FACEPLATE UP COVER
MANIPULATION BOX . . . . . . . . . . . . .
SCREW M3*6 ESP 220V . . . . . . . . . . .
SCREW M3*15 ESP 220V . . . . . . . . . .
OPERATION LABEL . . . . . . . . . . . . . .
FLOWMETER GAUGE JOINT )
xxx
xxx
FLOW METER GAUGE CABLE ESP2 .
FLOW METER GAUGE CABLE ESP3 .
CONTROL PC-MAIN BOARD . . . . . . .
16 xxx
17 01327 AS OPERATE FACEPLATE . . . . . . . . . $129.30
19 xxx
SOLID STATE RELAY 25A
GN84131011 ESP1 . . . . . . . . . . . . . .
SINGLE CABLE SSR-2-4 . . . . . . . . . .
(NOT SHOWN) ESP1 120V . . . . . . . . .
ELECTROMAGNETIC JOINT
(NOT SHOWN) ESP120V . . . . . . . . . .
38 xxx
18 xxx
xxx special order contact Cecilware for more information; unless indicated, parts are universal to all models
13
Water & Steam Assembly ESP1
Dia. Part
List
Price
Dia. Part
List
Price
#
1
2
3
4
5
6
7
8
Number Description
xxx
#
Number Description
WATER/STEAM TAP UNIT . . . . . .
TAP BODY . . . . . . . . . . . . . . . . . .
SEAL. . . . . . . . . . . . . . . . . . . . . . .
15 01332
16 xxx
17 xxx
18 xxx
19 01313
20 xxx
21 xxx
22 01312
23 xxx
24 xxx
25 01314
26 xxx
27 xxx
28 01337
HOT WATER KNOB CAP . . . . . . . $ 4.70
KIT STEAM TUBE . . . . . . . . . . . . .
NUT PIPE STEAM FOR SPRING .
KIT STEAM TUBE . . . . . . . . . . . . .
O-RING FOR ESP 220V . . . . . . . . $ 2.30
STEAM TAP WASHER . . . . . . . . .
STEAM TAP SPRING . . . . . . . . . .
PIPE GASKET TEFLON . . . . . . . . $ 2.90
STEAM SPRAYER. . . . . . . . . . . . .
ANTI SCORCHING CLIPS . . . . . .
O-RING. . . . . . . . . . . . . . . . . . . . . $ 2.90
HOT WATER TUBE . . . . . . . . . . . .
EXTERNAL SPRAYER. . . . . . . . . .
WATER STEAM TAPS ASSY. . . . . $ 133.90
xxx
01334
01335
xxx
$
.20
CHROMED TAP SHAFT . . . . . . . . $ 6.90
TAP CONNECTOR . . . . . . . . . . . .
O-RING. . . . . . . . . . . . . . . . . . . . . $ 1.50
TIGHTENING GASKET . . . . . . . . .
STEAM HOT WATER
01309
xxx
xxx
A VALVE SHAFT . . . . . . . . . . . . . .
STEAM TAP SPRING . . . . . . . . . .
GASKET . . . . . . . . . . . . . . . . . . . . $ 1.60
COPPER SEAL . . . . . . . . . . . . . . $ 3.80
BRASS NUT . . . . . . . . . . . . . . . . .
9
xxx
10 01308
11 01310
12 xxx
13 01311
14 01336
15 01333
"R" STEEL CIRCLIP . . . . . . . . . . .
$
.50
TAP KNOB . . . . . . . . . . . . . . . . . . $19.50
STEAM KNOB CAP . . . . . . . . . . . $ 4.70
xxx special order contact Cecilware for more information
14
Boiler ESP 1 Hydraulic Circuit
Dia. Part
List
Dia. Part
List
#
1
2
#
xxx
Description
BOILER . . . . . . . . . . . . . . . . . . . . . . . . . .
HEATING ELEMENT
Price
#
#
Description
Price
17 xxx
xxx
WATER LEVEL UPPER TUBE 220V MODELS
WATER LEVEL UPPER TUBE 110V MODELS
WATER LEVEL LOWER TUBE . . . . . . . .
AUT. WATER REFILL TUBE . . . . . . . . . .
AUT. WATER REFILL TUBE REAR . . . . .
PRESSURE GAUGE COPPER TUBE . . .
HEAT EXCHANGER OUTLET TUBE . . . .
HEAT EXCHANGER RETURN TUBE . . .
FLOWMETER INLET TUBE . . . . . . . . . .
S.C.N.R.DOSER VALVE 1/2*1/2*1/2 . . . .
HEAT EXCHANGER INLET TUBE . . . . . .
STEAM PRESSURE GAUGE TUBE . . . .
EXPANSION DRAIN TUBE . . . . . . . . . . .
BOILER DRAIN TUBE REAR . . . . . . . . .
PRESSURE RELEASE TAP BULK UNIT
PS1/4xPS1/4 . . . . . . . . . . . . . . . . . . . . .
BOILER DRAIN TUBE FRONT . . . . . . . .
HOT WATER OUTLET TUBE REAR . . . .
STEAM OUTLET TUBE FRONT
220V MODELS . . . . . . . . . . . . . . . . . . .
120V MODELS . . . . . . . . . . . . . . . . . . .
ELBOW BRASS CONNECTOR
xxx
01316
xxx
xxx
xxx
xxx
xxx
xxx
xxx
1500W 110V FOR ESP1 . . . . . . . . . . .
18 xxx
19 xxx
20 xxx
21 xxx
22 xxx
23 xxx
24 xxx
25 xxx
26 xxx
27 xxx
28 xxx
29 xxx
30 xxx
2000W 220V FOR ESP . . . . . . . . . . . $97.40
SI-GASKET ELEMENT . . . . . . . . . . . . . .
HEX SCREW (M10*16) . . . . . . . . . . . . . .
SAFETY VALVE . . . . . . . . . . . . . . . . . . . .
LEVEL PROBE ASSY . . . . . . . . . . . . . . .
VALVE GASKET BRASS . . . . . . . . . . . . .
ANTI-EDDY VALVE V.A.R. . . . . . . . . . . . .
VALVE GASKET BRASS . . . . . . . . . . . . .
ELBOW BRASS PT1/4*3/8 . . . . . . . . . . .
ELBOW BRASS
CONNECTOR 3/8*PT3/8 . . . . . . . . . . . .
BRASS CONNECTOR PT
1/4*1/2-20UNF*1/2-20UNF . . . . . . . . . .
BRASS CONNECTOR . . . . . . . . . . . . . .
SOL. VALVE WATER REFILL ASS.
3
4
5
6
7
8
9
10 xxx
11 xxx
12 xxx
31 xxx
32 xxx
33
13 xxx
14
xxx
110V 60 HZ FOR ESP 110V . . . . . . . .
208-240V 60Hz FOR ESP 220V . . . . . . $216.90
SPHERICAL BRONZE CONICAL FILTER
xxx
xxx
01324
15 xxx
34 xxx
16 01323 NBR O RING FOR ESP 220V . . . . . . . . .
$ .30
PT1/8 * PT1/4 . . . . . . . . . . . . . . . . . . . . .
xxx special order contact Cecilware for more information; unless indicated, parts are universal to all models
15
Boiler ESP 2 Hydraulic Circuit
Dia. Part
List
Dia. Part
List
#
1
2
3
4
5
6
7
8
9
#
xxx
Description
BOILER . . . . . . . . . . . . . . . . . . . . . . . . . .
Price
#
#
Description
Price
18 xxx
19 xxx
20 xxx
21 xxx
22 xxx
23 xxx
24 xxx
25 xxx
26 xxx
27 xxx
28 xxx
29 xxx
30 xxx
31 xxx
32 xxx
33 xxx
NBR O RING . . . . . . . . . . . . . . . . . . . . .
WATER LEVEL LOWER TUBE . . . . . . . .
AUT. WATER REFILL TUBE . . . . . . . . . .
AUT. WATER REFILL TUBE REAR . . . . .
PRESSURE GAUGE COPPER TUBE . . .
HEAT EXCHANGER OUTLET TUBE LEFT
HEAT EXCHANGER OUTLET TUBE RIGHT
HEAT EXCHANGER RETURN TUBE LEFT
HEAT EXCHANGER RETURN TUBE RIGHT
FLOWMETER INLET TUBE . . . . . . . . . .
S.C.N.R.DOSER VALVE 1/2*1/2*1/2 . . . .
HEAT EXCHANGER INLET TUBE . . . . .
STEAM PRESSURE GAUGE TUBE . . . .
EXPANSION DRAIN TUBE . . . . . . . . . . .
BOILER DRAIN TUBE REAR . . . . . . . . .
01315 HEATING ELEMENT 220V, 4000W . . . . .$ 118.80
xxx
xxx
xxx
xxx
xxx
xxx
xxx
SI-GASKET ELEMENT . . . . . . . . . . . . . .
HEX SCREW (M10*16) . . . . . . . . . . . . . .
SAFETY VALVE . . . . . . . . . . . . . . . . . . . .
LEVEL PROBE ASSY . . . . . . . . . . . . . . .
VALVE GASKET BRASS . . . . . . . . . . . . .
ANTI-EDDY VALVE V.A.R. . . . . . . . . . . .
VALVE GASKET BRASS . . . . . . . . . . . . .
HOT WATER CONDUCT
TUBE IN BOILER . . . . . . . . . . . . . . . . . .
ELBOW BRASS PT1/4*3/8 . . . . . . . . . . .
ELBOW BRASS CONNECTOR
3/8 * PT 3/8 . . . . . . . . . . . . . . . . . . . . . .
ELBOW BRASS CONNECTOR PT
10 xxx
11 xxx
12 xxx
13 xxx
14 xxx
1/8 * PT1/4 . . . . . . . . . . . . . . . . . . . . . . .
BRASS CONNECTOR PT
PRESSURE RELEASE TAP BULK UNIT
PS1/4xPS1/4 . . . . . . . . . . . . . . . . . . . . .
34 xxx
35 xxx
36 xxx
37 xxx
38 xxx
BOILER DRAIN TUBE FRONT . . . . . . . .
HOT WATER OUTLET TUBE REAR . . . .
STEAM OUTLET TUBE FRONT LEFT . .
STEAM OUTLET TUBE FRONT RIGHT .
WATER LEVEL UPPER TUBE . . . . . . . . .
1/4*1/2-20UNF*1/2-20UNF . . . . . . . . . .
BRASS CONNECTOR . . . . . . . . . . . . . .
SOL. VALVE WATER REFILL ASSY
208-240V 60Hz . . . . . . . . . . . . . . . . . . .
SPHERICAL BRONZE CONICAL FILTER
15 xxx
16 xxx
17 xxx
xxx special order contact Cecilware for more information
16
Boiler ESP 3 Hydraulic Circuit
Dia. Part
List
Dia. Part
List
#
1
2
3
4
5
6
#
xxx
Description
BOILER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Price
#
#
Description
Price
21 xxx
22 xxx
23 xxx
24 xxx
25 xxx
26 xxx
27 xxx
28 xxx
29 xxx
30 xxx
31 xxx
32 xxx
33 xxx
34 xxx
35 xxx
36 xxx
37 xxx
AUT.WATER REFILL TUBE REAR . . . . . . . . .
PRESSURE GAUGE COPPER TUBE . . . . . .
HEAT EXCHANGER OUTLET TUBE LEFT . .
HEAT EXCHANGER OUTLET TUBE RIGHT .
HEAT EXCHANGER OUTLET TUBE MIDDLE
HEAT EXCHANGER RETURN TUBE LEFT . .
HEAT EXCHANGER RETURN TUBE RIGHT .
HEAT EXCHANGER RETURN TUBE MIDDLE
FLOW METER INLET TUBE . . . . . . . . . . . . .
S.C.N.R.DOSER VALVE 1/2*1/2*1/2 . . . . . . .
HEAT EXCHANGER INLET TUBE LEFT . . . .
HEAT EXCHANGER INLET TUBE MIDDLE . .
HEAT EXCHANGER INLET TUBE RIGHT . . .
STEAM PRESSURE GAUGE TUBE . . . . . . .
EXPANSION DRAIN TUBE . . . . . . . . . . . . . .
BOILER DRAIN TUBE REAR . . . . . . . . . . . . .
PRESSURE RELEASE TAP
BULK UNIT PS1/4xPS1/4 . . . . . . . . . . . . . . .
BOILER DRAIN TUBE FRONT . . . . . . . . . . .
HOT WATER OUTLET TUBE REAR . . . . . . .
STEAM OUTLET TUBE FRONT LEFT . . . . . .
STEAM OUTLET TUBE FRONT RIGHT . . . .
WATER LEVEL UPPER TUBE . . . . . . . . . . . .
WATER LEVEL LOWER TUBE . . . . . . . . . . . .
ELBOW BRASS CONNECTOR PT1/8 * PT1/4
ELBOW BRASS CONNECTOR PF3/8 * PT1/8
01317 HEATING ELEMENT 6000W 220V . . . . . . . . $ 249.40
01318 SI-GASKET ELEMENT FOR 220V . . . . . . . . . $ 16.00
xxx
xxx
01320 LEVEL PROBE ASSY
FOR ESP 220V . . . . . . . . . . . . . . . . . . . . . . . $ 15.20
01321 VALVE GASKET BRASS
FOR ESP 220V . . . . . . . . . . . . . . . . . . . . . . .
01319 ANTI-EDDY VALVE V.A.R.
FOR ESP 220V . . . . . . . . . . . . . . . . . . . . . . . $ 19.50
01322 VALVE GASKET BRASS
FOR ESP 220V . . . . . . . . . . . . . . . . . . . . . . .
HOT WATER CONDUCT TUBE IN BOILER
HEX SCREW (M10*16) . . . . . . . . . . . . . . . . .
SAFETY VALVE . . . . . . . . . . . . . . . . . . . . . . .
7
8
9
$ 4.30
$ 3.40
10 xxx
11 xxx
12 xxx
13 xxx
14 xxx
.
ELBOW BRASS PT1/4*3/8 . . . . . . . . . . . . . .
ELBOW BRASS CONNECTOR 3/8*PT3/8 . .
AUT. WATER REFILL TUBE UPPER . . . . . . .
BRASS CONNECTOR
PT1/4*1/2-20UNF*1/2-20UNF . . . . . . . . . . .
BRASS CONNECTOR . . . . . . . . . . . . . . . . . .
SOL. VALVE WATER REFILL
ASSY 208-240V 60Hz . . . . . . . . . . . . . . . . . .
GROUP FILTER ST.STEEL D13.8*d10.5*11.5
NBR O RING . . . . . . . . . . . . . . . . . . . . . . . . .
AUT. WATER REFILL REDUCTION . . . . . . . .
AUT. WATER REFILL TUBE MIDDLE . . . . . .
38 xxx
39 xxx
40 xxx
41 xxx
42 xxx
43 xxx
44 xxx
45 xxx
15 xxx
16 xxx
17 xxx
18 xxx
19 xxx
20 xxx
xxx special order contact Cecilware for more information
17
Water Level Assembly ESP1
Dia. Part
List
#
1
2
#
Description
Price
xxx
xxx
xxx
LEVEL CONNECTOR (UPPER) . . . . . .
RUBBER GASKET (16*10*8) 110V MODEL .
SI-O-RING (7.5*2.5) 220V MODELS . .
3
01306 COPPER SEAL . . . . . . . . . . . . . . . . . . $ 1.50
4
5
xxx
xxx
BRASS NUT . . . . . . . . . . . . . . . . . . . . .
LEVEL-INDICATING BALL . . . . . . . . . .
6
01307 SIGHT GLASS FOR . . . . . . . . . . . . . . $ 9.20
7
8
9
10
11
12
xxx
xxx
xxx
xxx
xxx
xxx
SIGHT GLASS REAR COVER . . . . . . .
WASHER (M8*3t) . . . . . . . . . . . . . . . . .
HEX SCREW (M8*10) . . . . . . . . . . . . . .
PC PANEL . . . . . . . . . . . . . . . . . . . . . .
LEVEL LABEL . . . . . . . . . . . . . . . . . . .
LEVEL CONNECTOR (LOWER) . . . . . .
xxx special order contact Cecilware for more information;
Motor Pump Assembly ESP1, 2, 3
Dia. Part
List
#
#
Description
Price
1
01329 MOTOR FOR ESP 220V. . . . . . . . . $ 508.90
xxx MOTOR FOR ESP 120V. . . . . . . . .
01330 PUMP . . . . . . . . . . . . . . . . . . . . . . $ 444.00
2
3
4
5
6
7
xxx
xxx
xxx
xxx
xxx
PS 3/8"*PS1/2" GAS FITTING
PIPE GASKET TEFLON . . . . . . . . .
S.T. STEEL WIRE PIPE (60mm) . . .
S.T. STEEL WIRE PIPE (2400mm) .
CAPACITOR . . . . . . . . . . . . . . . . . .
xxx special order contact Cecilware for more information
18
Distribution Group Assembly ESP 1, 2, 3
Dia.
#
Part
#
List
Price
Description
1
2
3
4
5
6
7
xxx
xxx
01304
xxx
01300
xxx
DISTRIBUTION GROUP BODY . . . . . . . . . . . . . . . . . . . .
CHROMED CLAMPING RING . . . . . . . . . . . . . . . . . . . . .
O-RING d47*3.5t . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STAINLESS STEEL SCREW M5*10 . . . . . . . . . . . . . . . . .
FILTER SUPPORT RUBBER . . . . . . . . . . . . . . . . . . . . . .
WATER SPOUT UNIT SUPPORT . . . . . . . . . . . . . . . . . . .
GROUP SHOWER PLATE FOR ESP 120V . . . . . . . . . . . .
$ 4.00
$ 6.90
xxx
01301
01302
xxx
xxx
xxx
GROUP SHOWER PLATE FOR ESP 220V . . . . . . . . . . . . $ 21.60
8
9
STAINLESS STEEL FLATHEAD SCREW M5*15 . . . . . . . .
BRASS PLUG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GROUP ASBESTOS WASHER . . . . . . . . . . . . . . . . . . . . .
WATER MLET CONNECTOR . . . . . . . . . . . . . . . . . . . . . .
WATER RECYCLE CONNECTOR . . . . . . . . . . . . . . . . . . .
PT1/4x5/8-18UNF L FITTING . . . . . . . . . . . . . . . . . . . . .
PAEKER GROUP SOLENOID VALVE COIL
$ .40
10
11
12
13
14
xxx
xxx
xxx
01303
xxx
xxx
xxx
xxx
xxx
xxx
xxx
xxx
120V FOR ESP 120V . . . . . . . . . . . . . . . . . . . . . . . . . . .
208~240V 60Hz FOR ESP 220V . . . . . . . . . . . . . . . . . . $ 183.60
HEX SCREW M4*12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRESSURE RELEASE DRAIN TUBE FOR ESP 120V . . . .
PRESSURE RELEASE DRAIN TUBE FOR ESP 220V . . . .
GROUP JET D0.8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GROUP FILTER ST.STEEL D13.8*d10.5*11.5 . . . . . . . . . .
TEFLON GASKET D22*d18*2.0 . . . . . . . . . . . . . . . . . . . .
DISTRIBUTION GROUP CAP . . . . . . . . . . . . . . . . . . . . . .
DISTRIBUTION GROUP ASSY . . . . . . . . . . . . . . . . . . . . .
15
16
17
18
19
20
21
xxx special order contact Cecilware for more information
19
NOTES
Cecilware Corporation 43-05 20th. Avenue, LIC NY 11105
Tel: 800.935.2211 / 718.932.1414 • Fax: 718.932.7860
®
Since 1911
www.cecilware.com
20
|
Black Box Network Hardware Black Box Feed Through CAT6A Patch Panels User Manual
Black Decker Sander MS1000 User Manual
Bose Car Amplifier SA 4 User Manual
Boss Audio Systems Car Stereo System CCR612 User Manual
Boston Acoustics Speaker SUB10F User Manual
Bowers Wilkins Speaker CCM6 User Manual
Bradford White Corp Water Heater SW 2 65 L User Manual
BRK electronic Smoke Alarm SL177 User Manual
Broan Fan QTRE080R User Manual
Butler Coffeemaker 645 082 User Manual