Cecilware Espresso Maker ESP1 User Manual

®
Since 1911  
ESP Espresso Machines  
Instruction Manual  
Models: ESP1, ESP2 and ESP3  
Cecilware Corporation 43-05 20th. Avenue, LIC NY 11105  
Tel: 800.935.2211 / 718.932.1414 Fax: 718.932.7860  
®
Since 1911  
NR27A (05/08)  
www.cecilware.com  
 
1 General  
1-1  
1-2  
This operations manual includes instructions for using and maintaining your espresso  
machine, please keep this manual readily available.  
After unpacking, please check to ensure your machine has not been damaged during  
shipping and includes all parts/components. Please notify your service representative  
regarding any questions or concerns before installing. Please note that machine  
packaging material can be dangerous and should be kept out of reach of children.  
1-3  
Please confirm that your electricity supply conforms to the espresso machine power  
requirements. A qualified technician should install the machine in accordance with  
manufacturer instructions. The manufacturer assumes no responsibility for injury or  
damage resulting from improper installation.  
1-4  
1-5  
Please use an independent and suitable power source for your machine.  
Please use an independent, fuseless breaker appropriate to machine safety requirements.  
Do not plug your machine into an extension cord.  
1-6  
1-7  
Be sure to use a grounded power source to prevent electric shock and ensure operating  
safety.  
Use the automatic espresso machine for its intended purpose only. Any other usage is  
inappropriate and may be dangerous. The manufacturer assumes no responsibility for  
injury, loss or damage resulting from improper machine use.  
1-8  
Do Not:  
a. touch machine with wet hands or feet.  
b. touch machine with bare feet.  
c. pull on the cord to disconnect machine from power outlet.  
d. expose the espresso machine to rain or direct sunlight.  
e. permit children or persons not normally qualified to operate basic machinery to use  
this machine.  
1-9  
Turn off the power source first before maintaining or servicing your espresso machine.  
1-10 Take care when touching machine parts; subject to high temperature heating to avoid  
injury.  
1-11 Clean machine according to instructions provided in this manual to ensure proper  
operations.  
1-12 Turn power off if machine functions abnormally and notify qualified service personnel for  
repairs. Do not permit non-qualified service personnel to attempt repairs. Continuing to  
use a damaged or otherwise irregularly functioning machine will nullify the manufacturer  
warranty.  
3
 
1-13 Use softened water to make coffee or tea. Well / municipal water should be softened to  
prevent scaling in the boiler, which will shorten the serviceable life of your machine. If a  
hard water source is used, the filter should be replaced every two weeks -- although  
long-life filters may remain serviceable up to eight weeks. Actual filter replacement  
scheduling will vary based on volume and quality of water used.  
1-14 The machine refills water automatically (see Section 4-2 for initializing). An error code will  
appear if water flow into the machine exceeds two minutes (see Troubleshooting Section  
in this manual), and power will be cut off automatically to protect the system. To resume  
normal functions, restart the system after three or more seconds.  
1-15 The heating element will not operate when water in the machine is less than the minimum  
required level. When starting the machine without any water in the tank, heating will be  
delayed for about 60 seconds.  
1-16 Please ensure the water inside the piping will not be frozen while using the machine. The  
water temperature must maintain over the freezing point even during the power off  
period. The warranty does not cover any damages on piping and boiler cost by frozen  
water.  
1-17 When turning off the machine for long-term, please be sure to evacuate the water inside  
the piping completely. For this may freeze the water and lead to damaging the machine.  
To ensure the safety of your machine, please notify your service representative regarding  
any needs on operations in frigid zone or prepare to shut down the machine for long-term  
for complete water evacuation.  
2. Operating Precautions  
!
!
Do not use the machine and turn off the power when water intake has ceased.  
When operating the machine for the first time or replacing the filter, remove the water inlet  
tube and allow it to drain for about one minute in order to discharge impurities from the  
water.  
!
!
Please check and confirm normal water supply before turning on power.  
Please check and confirm water level registers within the green zone. Operating the  
machine outside the green zone may cause the electric heating element to overheat and  
burn out.  
!
!
After installing the machine, please check to make sure that, during water intake, the  
steam pressure gauge indicator is within the green zone (1~1.4bar) and the water  
pressure gauge indicator is also within the green zone (8~10bar). Please adjust the  
system to the water supply pressure conditions in your area.  
The water and steam taps are used to make coffee or tea. The nozzle at the hot water  
outlet and the steam outlet are very hot -- please do not touch.  
4
 
To avoid overheating, electric wires should be kept untangled and free of obstructions.  
Do not block air intake or outlet vents on the machine. Never cover or otherwise prevent  
the free flow of air across the cup warmer.  
!
!
!
!
Please clean machine components with a soft cloth only. Do not use plastic or wire  
brushes.  
Turn the power off and release all boiler pressure if the machine is to remain idle for an  
extended period of time.  
Place an appropriate quantity of ground coffee in the filter cup and tamper carefully.  
Clean all residual coffee from the rim and sides of the filter to ensure a good seal and full  
pressure for steaming and to maximize service life.  
!
!
!
The filter basket must be connected firmly to the filter support during steaming to avoid  
disengagement of the handle or overflow.  
Remove the cup from the steam tube after foaming milk. Failure to do so may draw  
liquid from the cup into the steam tube, risking machine component contamination.  
After machine power has been switched off, always let the machine set for at least 3  
seconds before restarting.  
3. Machine Overview  
A. Foot  
B. Water tray  
I. Manual water outlet controller  
J. Power indicator  
C. Pressure gauge (water/steam pressure)  
K. Power switch  
D. Steam tube  
L. Water level viewing window  
M. Manufacturer plate  
N. Filter basket handle  
O. Cup warming tray holder  
E. Hot water outlet nozzle  
F. Hot water control knob  
G. Steam control knob  
H. Control Panel  
5
 
4. Operations  
4-1 Activating / Deactivating the Water Inlet Motor  
a. If filtered water source pressure exceeds 2 bar and the amount of hot water needed is  
small, turn the water inlet motor (2) to the OFF (up) position to permit water inflow  
without internal pump assistance.  
b. In areas of low source water pressure, turn the water inlet motor (2) to the ON (down)  
position to activate the internal pump and draw water into the boiler mechanically.  
Caution: When source water pressure is low & turn the water inlet  
motor (2) to the OFF (up) position may risks drawing hot water away  
from the boiler and damaging the pump and water intake solenoid.  
4-2  
Starting the Automatic Machine  
a. Check and confirm that water source is in normal working order.  
b. Turn the power switch to position 1 to initiate automatic system check. If boiler water  
level is not in the green zone, wait until the automatic water replenishment process is  
complete before proceeding to the next step.  
c. Heating will stop when boiler pressure reaches approximately 1.2 bars (factory default  
setting). Do not operate machine until steam pressure gauge reading is in the green  
zone.  
4-3  
Using the Various Machine Functions  
a. Steam Output  
Turn steam knob counterclockwise to draw steam through the steam tube. Steam  
output will increase the further the steam knob is turned. Turn the knob clockwise to  
reduce/stop steam output. Pull out the steam knob when needing a good deal of  
steam for a short period of time.  
b. Hot Water Output  
Turn the hot water knob counterclockwise to obtain hot water through the hot water  
tube. Hot water output will increase the further the hot water knob is turned. Turn the  
knob clockwise to reduce/stop steam output. Pull out the hot water knob for hot water  
supply for a short period of time.  
6
 
c. Coffee / Tea Output Presets  
Place an appropriate quantity of ground coffee or tea in the filter basket and fix it into  
the handle seat. Choose desired water output by selecting coffee or tea output values  
1 through 4. Coffee or tea flow will stop automatically.  
d. Continuous Output & Stop  
Place an appropriate quantity of ground coffee or tea into the filter basket, and fix it  
into the handle seat. Press the manual output button to start coffee or tea flow. Press  
once again to stop.  
4-4  
Output Volume, Estimated steep time, and Frequency Setup  
There are two identical button suites on two-cup models and three identical button  
suites on 3-cup models. No default coffee / tea output setting is provided. Settings  
must be made manually during set-up. If you are using a multi-cup machine, settings  
made on the farthest right hand side button suite will serve as the default for the others.  
Therefore, to set different values for different cup compartments, begin set up from the  
right and work your way to the left, to prevent the previous setting been covered.  
Manual Output Button  
Control Panel  
7
 
Output Volume Setup  
a. Turn the output volume setup switch ON (1) and press the PROG (setup) button.  
LED  
Setup Button  
Output Keys  
b. The output LEDs should be lit, indicating the machine is in setup mode.  
c. To configure key 1, press the key 1 button, which should light LED 1 and switch off all  
other LEDs. Once desired setup parameters have been set, press key 1 again to  
confirm and exit key 1 setup.  
d. At this point, LED 1 should be off and LED's 2, 3 and 4 should be lit.  
e. Repeat steps (b) through (d) to set up keys 2, 3 and 4, respectively.  
f. The left set(s) of keys will mirror the value settings in the set of keys to its immediate  
right. Repeat steps (b) through (e) if different output volumes are desired for different  
cup compartments.  
g. After completing setup, turn the output volume setup switch OFF (1) to return the  
machine to normal operational mode.  
4-5  
Automatic Reverse Flushing  
a. Press any key simultaneously to start automatic reverse flushing. Keys 2-4 in the  
control panel will start flashing and start automatic reverse flushing from the right  
output system to the left.  
b. The default is 10 cleaning cycles.  
c. Flush the second output system after flushing the first output system. Or press the 3rd  
key to skip to the next output system, System will stop automatically after finish all the  
reverse flushing.  
4-6  
Stopping the Machine  
a. After cleaning the machine, remove all liquids and solid matter from the water tray.  
b. Turn off the power (turn power switch to position 0).  
c. Open steam knob to release steam flow. Do not place any liquid under the steam tube  
during this process in to avoid system contamination.  
5. Cleaning and Maintenance  
5-1 Cleaning the Machine Body  
Wipe machine exterior with soft, slightly dampened cloth daily before starting operations.  
8
 
If necessary, a mild, non-corrosive cleaning agent may be applied to the cloth. Do not  
spray cleaning agents directly on the machine body to avoid corrosion and possible  
damage to circuits.  
5-2 Brewing System  
After each brewing cycle, remove the handle and press the manual water output button to  
remove all residual ground coffee from the filter element. Then, fix the handle to the seat  
again (Important: Do not force handle or fix it into the seat too tightly). Press the manual  
water output button, shake the handle to clean the handle seat gasket and remove  
residual coffee grounds from the along the inside.  
A Flush the steam outlet in REVERSE daily before shutting off the machine.  
Remove the copper plate and filter element from the water outlet (be careful, metal  
components may be hot).  
B Place a reverse flushing silica plate in the filter cup, and apply about 2-3 grams of  
detergent. Fix the handle into the seat and check for tightness.  
C To dissolve residual detergent in the machine, press the manual water output button  
for approximately 4 seconds and release. Repeat this process several times. Press  
the manual water output button and shake the handle to clean the gasket and the  
inside of the brewer. Continue the process until water in the filter cup is clear and  
clean.  
D After cleaning, remove the handle. Press the manual water output button to allow  
residual cleaning solution in the brewing system to flow out. Turn water off after  
flushing for about one minute.  
a. During reverse flushing, remove and wash the copper plate and filter element with  
clean tap water. Wipe with soft cloth.  
b. If process is unable to sufficiently clean the plate and filter element, immerse the  
components overnight in a mild cleaning solution of 3 tsp detergent in 1 pint hot water.  
Rinse and reassemble components before restarting the espresso machine.  
5-3  
Filter Basket and Basket Handle  
a. Rinse the handle with hot water after each brewing cycle to dissolve residual oils in the  
filter basket and outlet nozzle and prevent oils from affecting the quality of coffee.  
b. Disassemble filter basket handle and filter basket. Immerse both in cleaning solution  
(3tsp of detergent in 1 pint hot water) for 24 hours to dissolve residual coffee oils.  
Important: Do not immerse the plastic portion of the handle in the cleaning solution to  
avoid deterioration.  
C. Rinse all components with clean water. Wipe with a soft, clean cloth only.  
9
 
Dia. Part  
List  
#
1
2
3
4
#
Description  
Price  
01346 SILICA GEL WASHER . . . . . . . . . . . . $ 2.10  
01347 1 CUP FILTER HOLDER ASSY . . . . . 156.40  
01348 1 CUP STAINLESS STEEL FILTER . .  
01349 1 CUP FILTER HOLDER  
24.60  
WITHOUT FILTER . . . . . . . . . . . . . . . 121.20  
5
6
7
8
9
01350 FILTER SUPPORT . . . . . . . . . . . . . . .  
01351 BRASS SPOUT 1 LONG CUP . . . . . .  
01352 FILTER CLAMP SPRING D1.4 . . . . . .  
01353 FILTER HOLDER KNOB CAP . . . . . .  
01354 FILTER HOLDER BACK LID . . . . . . .  
83.70  
23.40  
1.00  
14.00  
1.50  
10 01355 2 CUPS FILTER HOLDER ASSY . . . . 163.00  
11 01356 2 CUPS STAINLESS STEEL FILTER .  
12 01357 2 CUPS FILTER HOLDER  
24.60  
WITHOUT FILTER . . . . . . . . . . . . . . . 127.90  
13 01358 2 CUPS BRASS SPOUT . . . . . . . . . . 30.00  
5-4  
5-5  
Steam Tube  
a. After making steamed milk, use a slightly moistened soft cloth to wipe steam tube.  
After wiping, release a steam burst through the tube to remove any residual milk  
remaining in the nozzle.  
b. If hardened milk residuals remain in the steam tube, disassemble and immerse tube in  
hot water for about 20 minutes to soften. Reassemble and repeat step (a).  
Boiler  
To extend your boiler’s serviceable life, when the machine is expected to sit idle for a  
period of one or more days, turn power to the machine OFF and open the steam  
output to discharge pressure in the boiler. Continue until the pressure gauge reading  
falls to zero and steam discharge ends. Once complete, empty and clean the water  
tray and discharge trough. (Important: Leave the steam output setting open following  
steam discharge. Steam output should remain open until after the machine is turned  
back on and hot water begins dripping from the steam tube.  
5-6  
5-7  
Water Tray  
Remove and wash the water tray after stopping your automatic machine. Reassemble  
after the water tray has dried.  
Discharge Trough  
a. After removing the water tray, wipe and remove sediments in the discharge trough with  
a wet cloth or napkin and wash with hot water to clear the discharge tube.  
b. If water does not discharge properly, place a teaspoon of detergent into the discharge  
trough and flush with hot water to dissolve residual oils in the tube.  
5-8  
Filter  
a. The manufacturer recommends replacing the filter element on the resin exchange filter  
after processing 53 gallons of water (about 3,000 – 4,000 cups of coffee). This  
schedule can be expected to vary based on the quality of water used in your machine.  
10  
 
6 Trouble Shooting  
Corrective  
Actions  
Indication  
Status  
Possible Cause  
After two minutes of  
1. Make sure that the water  
input switch is ON and  
that water is flowing into  
the machine.  
water input, indicator  
still does not show a  
rise in machine water  
level. It will take more  
than two minutes to  
replenish water when  
the machine is used  
for the first time.  
1. Water level indicator not  
functioning properly.  
2. Water intake solenoid is  
L
out of order. Input water 2. Turn off the machine.  
flow has been  
interrupted.  
Restart after 3 seconds.  
3. Notify local dealer.  
1. No water output from 1. Coffee grounds are too 1. Adjust coffee ground  
the brewer.  
2. Machine does not  
reach preset  
fine.  
fineness.  
2. Ensure water input is  
normal.  
E
2. No water input  
3. Water intake solenoid is  
out of order.  
parameters.  
3. Notify local dealer.  
Boiler water level is too  
low, automatic water  
input system is working.  
Boiler is in automatic  
water input mode.  
Indication of an action for  
reference.  
.
1. Turn machine off.Restart  
after 3 seconds.  
2. Notify local dealer.  
IC board does not  
function properly.  
Software or hardware  
error.  
A or B  
Wait at least 3 seconds to restart the automatic espresso machine after turning it off to ensure  
previous data stored in machine memory is erased. Turning the machine on too quickly may  
cause the machine to function improperly.  
11  
 
7. Replacement Parts (For Reference Only)  
Item  
1
Particular  
Brewer gasket  
Serviceable Life  
3 - 6 months, depending of volume  
of coffee brewed  
2
3
4
5
6
7
8
Upper gasket for steam tube  
Lower gasket for steam tube  
Leak-stop gasket for steam/hot water valve  
Upper gasket for steam/hot water valve  
Pressure relief valve  
1 year  
1 year  
1 year  
1 year  
2 years  
2 years  
Safety valve  
Filter pad  
1 – 3 months, depending on water  
quality  
9
Filter element (active carbon)  
Filter element (soft water resin)  
1 – 3 months, depending on water  
quality  
1 – 3 months, depending on water  
quality  
10  
Overall Composition Chart ESP1, ESP2, ESP3  
Dia. Part  
List  
Dia. Part  
List  
#
1
2
3
4
5
6
7
8
#
Description  
Price  
#
9
#
xxx  
Description  
Price  
xxx  
xxx  
xxx  
xxx  
SCREW M4*8 . . . . . . . . . . . . . . . . . .  
NUT M10 . . . . . . . . . . . . . . . . . . . . . .  
SPRING WASHER M10 . . . . . . . . . . .  
DRAIN BASIN . . . . . . . . . . . . . . . . . .  
FLOWMETER DOSER ASSY . . . . . . .  
NUT M6 . . . . . . . . . . . . . . . . . . . . . . .  
SPRING WASHER M6 . . . . . . . . . . . .  
ANTI FOOT VIBRATION . . . . . . . . . . .  
10 xxx  
11 xxx  
12 xxx  
01325 FLOWMETER DOSER . . . . . . . . . . . $161.50  
13 01331 PRESSURE GAUGE FOR ESP 220V . $188.20  
xxx  
xxx  
xxx  
BRASS FITTING PS/1/4*PS1/4*L33.5  
BRASS FITTING PS/1/4*PS1/4*L42 .  
SCREW M4*6 . . . . . . . . . . . . . . . . . .  
14 xxx  
15. xxx  
16. xxx  
PRESSURE GAUGE . . . . . . . . . . . . .  
SCREW M8*20  
SPRING WASHER M8  
xxx special order contact Cecilware for more information  
12  
 
Electrical Assembly  
Dia. Part  
List  
Dia. Part  
List  
#
#
Description  
Price  
#
#
Description  
Price  
1
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
MAIN SWITCH ASSY ESP1 . . . . . . . .  
MAIN SWITCH ASSY ESP2 . . . . . . . .  
MAIN SWITCH ASSY ESP3 . . . . . . . .  
MAIN SWITCH ESP1, 2 . . . . . . . . . . .  
MAIN SWITCH ESP3 . . . . . . . . . . . . . .  
CABLE UNIT ESP1 . . . . . . . . . . . . . . .  
CABLE UNIT ESP2 . . . . . . . . . . . . . . .  
CABLE UNIT ESP3 . . . . . . . . . . . . . . .  
LUMINOUS BLACK BIPOLAR . . . . . .  
GREEN INDICATOR LAMP . . . . . . . . .  
xxx  
SOLID STATE RELAY 50A  
GN84137021 ESP2, ESP3 . . . . . . . . .  
20 xxx  
SINGLE CABLE  
2
3
PRESSURE SWITCH<->PCB . . . . . .  
MOTOR POWER ESP1,120V . . . . . . .  
MOTOR POWER ESP1, 220V . . . . . . .  
MOTOR POWER ESP2 . . . . . . . . . . . .  
MOTOR POWER ESP3 . . . . . . . . . . . .  
SSR-PRESSURE SWITCH CABLE . . .  
FAN FOR SSR . . . . . . . . . . . . . . . . . .  
RADIATOR . . . . . . . . . . . . . . . . . . . . .  
MAIN SWITCH COVER . . . . . . . . . . . .  
BAND . . . . . . . . . . . . . . . . . . . . . . . . .  
MAIN SWITCH HAND GRIP LABEL PLATE  
MAIN SWITCH HAND GRIP . . . . . . . .  
SSR HOLDER . . . . . . . . . . . . . . . . . . .  
21 xxx  
xxx  
xxx  
xxx  
4
5
6
22 xxx  
23 xxx  
24 xxx  
25 xxx  
26 xxx  
27 xxx  
28 xxx  
29 xxx  
01326 SI 501 CE PRESSURE SWITCH  
110V / 240V AC 20A . . . . . . . . . . . . . $ 319.50  
CONTROL BOX WITH IC BOARD . . . .  
01328 CONTROL PC-MAIN BOARD . . . . . . . $ 400.40  
7
8
9
xxx  
xxx  
xxx  
FUSE 1.5A . . . . . . . . . . . . . . . . . . . . . .  
FUSE 4A (MOTOR) . . . . . . . . . . . . . . .  
SERIES CABLE PCB PANEL . . . . . . . .  
SERIES CABLE PANEL . . . . . . . . . . . .  
SELECT SWITCH . . . . . . . . . . . . . . . .  
LEVEL PROBE CABLE . . . . . . . . . . . .  
HEATING ELEMENT POWER CABLE .  
FLOWMETER GAUGE CABLE ESP1 .  
10 xxx  
11 xxx  
12 xxx  
13 xxx  
14 xxx  
15 xxx  
30 01338 TEMP. PROTECTION FUSE . . . . . . . .  
$ 8.60  
31 xxx  
xxx  
CONTROL BOX WITHOUT IC  
BOARD (UP & DOWN COVER) . . . . . .  
32 xxx  
33 xxx  
34 xxx  
35 xxx  
36 xxx  
37 xxx  
AS MANIPULATION FACEPLATE UP COVER  
MANIPULATION BOX . . . . . . . . . . . . .  
SCREW M3*6 ESP 220V . . . . . . . . . . .  
SCREW M3*15 ESP 220V . . . . . . . . . .  
OPERATION LABEL . . . . . . . . . . . . . .  
FLOWMETER GAUGE JOINT )  
xxx  
xxx  
FLOW METER GAUGE CABLE ESP2 .  
FLOW METER GAUGE CABLE ESP3 .  
CONTROL PC-MAIN BOARD . . . . . . .  
16 xxx  
17 01327 AS OPERATE FACEPLATE . . . . . . . . . $129.30  
19 xxx  
SOLID STATE RELAY 25A  
GN84131011 ESP1 . . . . . . . . . . . . . .  
SINGLE CABLE SSR-2-4 . . . . . . . . . .  
(NOT SHOWN) ESP1 120V . . . . . . . . .  
ELECTROMAGNETIC JOINT  
(NOT SHOWN) ESP120V . . . . . . . . . .  
38 xxx  
18 xxx  
xxx special order contact Cecilware for more information; unless indicated, parts are universal to all models  
13  
 
Water & Steam Assembly ESP1  
Dia. Part  
List  
Price  
Dia. Part  
List  
Price  
#
1
2
3
4
5
6
7
8
Number Description  
xxx  
#
Number Description  
WATER/STEAM TAP UNIT . . . . . .  
TAP BODY . . . . . . . . . . . . . . . . . .  
SEAL. . . . . . . . . . . . . . . . . . . . . . .  
15 01332  
16 xxx  
17 xxx  
18 xxx  
19 01313  
20 xxx  
21 xxx  
22 01312  
23 xxx  
24 xxx  
25 01314  
26 xxx  
27 xxx  
28 01337  
HOT WATER KNOB CAP . . . . . . . $ 4.70  
KIT STEAM TUBE . . . . . . . . . . . . .  
NUT PIPE STEAM FOR SPRING .  
KIT STEAM TUBE . . . . . . . . . . . . .  
O-RING FOR ESP 220V . . . . . . . . $ 2.30  
STEAM TAP WASHER . . . . . . . . .  
STEAM TAP SPRING . . . . . . . . . .  
PIPE GASKET TEFLON . . . . . . . . $ 2.90  
STEAM SPRAYER. . . . . . . . . . . . .  
ANTI SCORCHING CLIPS . . . . . .  
O-RING. . . . . . . . . . . . . . . . . . . . . $ 2.90  
HOT WATER TUBE . . . . . . . . . . . .  
EXTERNAL SPRAYER. . . . . . . . . .  
WATER STEAM TAPS ASSY. . . . . $ 133.90  
xxx  
01334  
01335  
xxx  
$
.20  
CHROMED TAP SHAFT . . . . . . . . $ 6.90  
TAP CONNECTOR . . . . . . . . . . . .  
O-RING. . . . . . . . . . . . . . . . . . . . . $ 1.50  
TIGHTENING GASKET . . . . . . . . .  
STEAM HOT WATER  
01309  
xxx  
xxx  
A VALVE SHAFT . . . . . . . . . . . . . .  
STEAM TAP SPRING . . . . . . . . . .  
GASKET . . . . . . . . . . . . . . . . . . . . $ 1.60  
COPPER SEAL . . . . . . . . . . . . . . $ 3.80  
BRASS NUT . . . . . . . . . . . . . . . . .  
9
xxx  
10 01308  
11 01310  
12 xxx  
13 01311  
14 01336  
15 01333  
"R" STEEL CIRCLIP . . . . . . . . . . .  
$
.50  
TAP KNOB . . . . . . . . . . . . . . . . . . $19.50  
STEAM KNOB CAP . . . . . . . . . . . $ 4.70  
xxx special order contact Cecilware for more information  
14  
 
Boiler ESP 1 Hydraulic Circuit  
Dia. Part  
List  
Dia. Part  
List  
#
1
2
#
xxx  
Description  
BOILER . . . . . . . . . . . . . . . . . . . . . . . . . .  
HEATING ELEMENT  
Price  
#
#
Description  
Price  
17 xxx  
xxx  
WATER LEVEL UPPER TUBE 220V MODELS  
WATER LEVEL UPPER TUBE 110V MODELS  
WATER LEVEL LOWER TUBE . . . . . . . .  
AUT. WATER REFILL TUBE . . . . . . . . . .  
AUT. WATER REFILL TUBE REAR . . . . .  
PRESSURE GAUGE COPPER TUBE . . .  
HEAT EXCHANGER OUTLET TUBE . . . .  
HEAT EXCHANGER RETURN TUBE . . .  
FLOWMETER INLET TUBE . . . . . . . . . .  
S.C.N.R.DOSER VALVE 1/2*1/2*1/2 . . . .  
HEAT EXCHANGER INLET TUBE . . . . . .  
STEAM PRESSURE GAUGE TUBE . . . .  
EXPANSION DRAIN TUBE . . . . . . . . . . .  
BOILER DRAIN TUBE REAR . . . . . . . . .  
PRESSURE RELEASE TAP BULK UNIT  
PS1/4xPS1/4 . . . . . . . . . . . . . . . . . . . . .  
BOILER DRAIN TUBE FRONT . . . . . . . .  
HOT WATER OUTLET TUBE REAR . . . .  
STEAM OUTLET TUBE FRONT  
220V MODELS . . . . . . . . . . . . . . . . . . .  
120V MODELS . . . . . . . . . . . . . . . . . . .  
ELBOW BRASS CONNECTOR  
xxx  
01316  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
1500W 110V FOR ESP1 . . . . . . . . . . .  
18 xxx  
19 xxx  
20 xxx  
21 xxx  
22 xxx  
23 xxx  
24 xxx  
25 xxx  
26 xxx  
27 xxx  
28 xxx  
29 xxx  
30 xxx  
2000W 220V FOR ESP . . . . . . . . . . . $97.40  
SI-GASKET ELEMENT . . . . . . . . . . . . . .  
HEX SCREW (M10*16) . . . . . . . . . . . . . .  
SAFETY VALVE . . . . . . . . . . . . . . . . . . . .  
LEVEL PROBE ASSY . . . . . . . . . . . . . . .  
VALVE GASKET BRASS . . . . . . . . . . . . .  
ANTI-EDDY VALVE V.A.R. . . . . . . . . . . . .  
VALVE GASKET BRASS . . . . . . . . . . . . .  
ELBOW BRASS PT1/4*3/8 . . . . . . . . . . .  
ELBOW BRASS  
CONNECTOR 3/8*PT3/8 . . . . . . . . . . . .  
BRASS CONNECTOR PT  
1/4*1/2-20UNF*1/2-20UNF . . . . . . . . . .  
BRASS CONNECTOR . . . . . . . . . . . . . .  
SOL. VALVE WATER REFILL ASS.  
3
4
5
6
7
8
9
10 xxx  
11 xxx  
12 xxx  
31 xxx  
32 xxx  
33  
13 xxx  
14  
xxx  
110V 60 HZ FOR ESP 110V . . . . . . . .  
208-240V 60Hz FOR ESP 220V . . . . . . $216.90  
SPHERICAL BRONZE CONICAL FILTER  
xxx  
xxx  
01324  
15 xxx  
34 xxx  
16 01323 NBR O RING FOR ESP 220V . . . . . . . . .  
$ .30  
PT1/8 * PT1/4 . . . . . . . . . . . . . . . . . . . . .  
xxx special order contact Cecilware for more information; unless indicated, parts are universal to all models  
15  
 
Boiler ESP 2 Hydraulic Circuit  
Dia. Part  
List  
Dia. Part  
List  
#
1
2
3
4
5
6
7
8
9
#
xxx  
Description  
BOILER . . . . . . . . . . . . . . . . . . . . . . . . . .  
Price  
#
#
Description  
Price  
18 xxx  
19 xxx  
20 xxx  
21 xxx  
22 xxx  
23 xxx  
24 xxx  
25 xxx  
26 xxx  
27 xxx  
28 xxx  
29 xxx  
30 xxx  
31 xxx  
32 xxx  
33 xxx  
NBR O RING . . . . . . . . . . . . . . . . . . . . .  
WATER LEVEL LOWER TUBE . . . . . . . .  
AUT. WATER REFILL TUBE . . . . . . . . . .  
AUT. WATER REFILL TUBE REAR . . . . .  
PRESSURE GAUGE COPPER TUBE . . .  
HEAT EXCHANGER OUTLET TUBE LEFT  
HEAT EXCHANGER OUTLET TUBE RIGHT  
HEAT EXCHANGER RETURN TUBE LEFT  
HEAT EXCHANGER RETURN TUBE RIGHT  
FLOWMETER INLET TUBE . . . . . . . . . .  
S.C.N.R.DOSER VALVE 1/2*1/2*1/2 . . . .  
HEAT EXCHANGER INLET TUBE . . . . .  
STEAM PRESSURE GAUGE TUBE . . . .  
EXPANSION DRAIN TUBE . . . . . . . . . . .  
BOILER DRAIN TUBE REAR . . . . . . . . .  
01315 HEATING ELEMENT 220V, 4000W . . . . .$ 118.80  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
SI-GASKET ELEMENT . . . . . . . . . . . . . .  
HEX SCREW (M10*16) . . . . . . . . . . . . . .  
SAFETY VALVE . . . . . . . . . . . . . . . . . . . .  
LEVEL PROBE ASSY . . . . . . . . . . . . . . .  
VALVE GASKET BRASS . . . . . . . . . . . . .  
ANTI-EDDY VALVE V.A.R. . . . . . . . . . . .  
VALVE GASKET BRASS . . . . . . . . . . . . .  
HOT WATER CONDUCT  
TUBE IN BOILER . . . . . . . . . . . . . . . . . .  
ELBOW BRASS PT1/4*3/8 . . . . . . . . . . .  
ELBOW BRASS CONNECTOR  
3/8 * PT 3/8 . . . . . . . . . . . . . . . . . . . . . .  
ELBOW BRASS CONNECTOR PT  
10 xxx  
11 xxx  
12 xxx  
13 xxx  
14 xxx  
1/8 * PT1/4 . . . . . . . . . . . . . . . . . . . . . . .  
BRASS CONNECTOR PT  
PRESSURE RELEASE TAP BULK UNIT  
PS1/4xPS1/4 . . . . . . . . . . . . . . . . . . . . .  
34 xxx  
35 xxx  
36 xxx  
37 xxx  
38 xxx  
BOILER DRAIN TUBE FRONT . . . . . . . .  
HOT WATER OUTLET TUBE REAR . . . .  
STEAM OUTLET TUBE FRONT LEFT . .  
STEAM OUTLET TUBE FRONT RIGHT .  
WATER LEVEL UPPER TUBE . . . . . . . . .  
1/4*1/2-20UNF*1/2-20UNF . . . . . . . . . .  
BRASS CONNECTOR . . . . . . . . . . . . . .  
SOL. VALVE WATER REFILL ASSY  
208-240V 60Hz . . . . . . . . . . . . . . . . . . .  
SPHERICAL BRONZE CONICAL FILTER  
15 xxx  
16 xxx  
17 xxx  
xxx special order contact Cecilware for more information  
16  
 
Boiler ESP 3 Hydraulic Circuit  
Dia. Part  
List  
Dia. Part  
List  
#
1
2
3
4
5
6
#
xxx  
Description  
BOILER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Price  
#
#
Description  
Price  
21 xxx  
22 xxx  
23 xxx  
24 xxx  
25 xxx  
26 xxx  
27 xxx  
28 xxx  
29 xxx  
30 xxx  
31 xxx  
32 xxx  
33 xxx  
34 xxx  
35 xxx  
36 xxx  
37 xxx  
AUT.WATER REFILL TUBE REAR . . . . . . . . .  
PRESSURE GAUGE COPPER TUBE . . . . . .  
HEAT EXCHANGER OUTLET TUBE LEFT . .  
HEAT EXCHANGER OUTLET TUBE RIGHT .  
HEAT EXCHANGER OUTLET TUBE MIDDLE  
HEAT EXCHANGER RETURN TUBE LEFT . .  
HEAT EXCHANGER RETURN TUBE RIGHT .  
HEAT EXCHANGER RETURN TUBE MIDDLE  
FLOW METER INLET TUBE . . . . . . . . . . . . .  
S.C.N.R.DOSER VALVE 1/2*1/2*1/2 . . . . . . .  
HEAT EXCHANGER INLET TUBE LEFT . . . .  
HEAT EXCHANGER INLET TUBE MIDDLE . .  
HEAT EXCHANGER INLET TUBE RIGHT . . .  
STEAM PRESSURE GAUGE TUBE . . . . . . .  
EXPANSION DRAIN TUBE . . . . . . . . . . . . . .  
BOILER DRAIN TUBE REAR . . . . . . . . . . . . .  
PRESSURE RELEASE TAP  
BULK UNIT PS1/4xPS1/4 . . . . . . . . . . . . . . .  
BOILER DRAIN TUBE FRONT . . . . . . . . . . .  
HOT WATER OUTLET TUBE REAR . . . . . . .  
STEAM OUTLET TUBE FRONT LEFT . . . . . .  
STEAM OUTLET TUBE FRONT RIGHT . . . .  
WATER LEVEL UPPER TUBE . . . . . . . . . . . .  
WATER LEVEL LOWER TUBE . . . . . . . . . . . .  
ELBOW BRASS CONNECTOR PT1/8 * PT1/4  
ELBOW BRASS CONNECTOR PF3/8 * PT1/8  
01317 HEATING ELEMENT 6000W 220V . . . . . . . . $ 249.40  
01318 SI-GASKET ELEMENT FOR 220V . . . . . . . . . $ 16.00  
xxx  
xxx  
01320 LEVEL PROBE ASSY  
FOR ESP 220V . . . . . . . . . . . . . . . . . . . . . . . $ 15.20  
01321 VALVE GASKET BRASS  
FOR ESP 220V . . . . . . . . . . . . . . . . . . . . . . .  
01319 ANTI-EDDY VALVE V.A.R.  
FOR ESP 220V . . . . . . . . . . . . . . . . . . . . . . . $ 19.50  
01322 VALVE GASKET BRASS  
FOR ESP 220V . . . . . . . . . . . . . . . . . . . . . . .  
HOT WATER CONDUCT TUBE IN BOILER  
HEX SCREW (M10*16) . . . . . . . . . . . . . . . . .  
SAFETY VALVE . . . . . . . . . . . . . . . . . . . . . . .  
7
8
9
$ 4.30  
$ 3.40  
10 xxx  
11 xxx  
12 xxx  
13 xxx  
14 xxx  
.
ELBOW BRASS PT1/4*3/8 . . . . . . . . . . . . . .  
ELBOW BRASS CONNECTOR 3/8*PT3/8 . .  
AUT. WATER REFILL TUBE UPPER . . . . . . .  
BRASS CONNECTOR  
PT1/4*1/2-20UNF*1/2-20UNF . . . . . . . . . . .  
BRASS CONNECTOR . . . . . . . . . . . . . . . . . .  
SOL. VALVE WATER REFILL  
ASSY 208-240V 60Hz . . . . . . . . . . . . . . . . . .  
GROUP FILTER ST.STEEL D13.8*d10.5*11.5  
NBR O RING . . . . . . . . . . . . . . . . . . . . . . . . .  
AUT. WATER REFILL REDUCTION . . . . . . . .  
AUT. WATER REFILL TUBE MIDDLE . . . . . .  
38 xxx  
39 xxx  
40 xxx  
41 xxx  
42 xxx  
43 xxx  
44 xxx  
45 xxx  
15 xxx  
16 xxx  
17 xxx  
18 xxx  
19 xxx  
20 xxx  
xxx special order contact Cecilware for more information  
17  
 
Water Level Assembly ESP1  
Dia. Part  
List  
#
1
2
#
Description  
Price  
xxx  
xxx  
xxx  
LEVEL CONNECTOR (UPPER) . . . . . .  
RUBBER GASKET (16*10*8) 110V MODEL .  
SI-O-RING (7.5*2.5) 220V MODELS . .  
3
01306 COPPER SEAL . . . . . . . . . . . . . . . . . . $ 1.50  
4
5
xxx  
xxx  
BRASS NUT . . . . . . . . . . . . . . . . . . . . .  
LEVEL-INDICATING BALL . . . . . . . . . .  
6
01307 SIGHT GLASS FOR . . . . . . . . . . . . . . $ 9.20  
7
8
9
10  
11  
12  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
SIGHT GLASS REAR COVER . . . . . . .  
WASHER (M8*3t) . . . . . . . . . . . . . . . . .  
HEX SCREW (M8*10) . . . . . . . . . . . . . .  
PC PANEL . . . . . . . . . . . . . . . . . . . . . .  
LEVEL LABEL . . . . . . . . . . . . . . . . . . .  
LEVEL CONNECTOR (LOWER) . . . . . .  
xxx special order contact Cecilware for more information;  
Motor Pump Assembly ESP1, 2, 3  
Dia. Part  
List  
#
#
Description  
Price  
1
01329 MOTOR FOR ESP 220V. . . . . . . . . $ 508.90  
xxx MOTOR FOR ESP 120V. . . . . . . . .  
01330 PUMP . . . . . . . . . . . . . . . . . . . . . . $ 444.00  
2
3
4
5
6
7
xxx  
xxx  
xxx  
xxx  
xxx  
PS 3/8"*PS1/2" GAS FITTING  
PIPE GASKET TEFLON . . . . . . . . .  
S.T. STEEL WIRE PIPE (60mm) . . .  
S.T. STEEL WIRE PIPE (2400mm) .  
CAPACITOR . . . . . . . . . . . . . . . . . .  
xxx special order contact Cecilware for more information  
18  
 
Distribution Group Assembly ESP 1, 2, 3  
Dia.  
#
Part  
#
List  
Price  
Description  
1
2
3
4
5
6
7
xxx  
xxx  
01304  
xxx  
01300  
xxx  
DISTRIBUTION GROUP BODY . . . . . . . . . . . . . . . . . . . .  
CHROMED CLAMPING RING . . . . . . . . . . . . . . . . . . . . .  
O-RING d47*3.5t . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
STAINLESS STEEL SCREW M5*10 . . . . . . . . . . . . . . . . .  
FILTER SUPPORT RUBBER . . . . . . . . . . . . . . . . . . . . . .  
WATER SPOUT UNIT SUPPORT . . . . . . . . . . . . . . . . . . .  
GROUP SHOWER PLATE FOR ESP 120V . . . . . . . . . . . .  
$ 4.00  
$ 6.90  
xxx  
01301  
01302  
xxx  
xxx  
xxx  
GROUP SHOWER PLATE FOR ESP 220V . . . . . . . . . . . . $ 21.60  
8
9
STAINLESS STEEL FLATHEAD SCREW M5*15 . . . . . . . .  
BRASS PLUG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
GROUP ASBESTOS WASHER . . . . . . . . . . . . . . . . . . . . .  
WATER MLET CONNECTOR . . . . . . . . . . . . . . . . . . . . . .  
WATER RECYCLE CONNECTOR . . . . . . . . . . . . . . . . . . .  
PT1/4x5/8-18UNF L FITTING . . . . . . . . . . . . . . . . . . . . .  
PAEKER GROUP SOLENOID VALVE COIL  
$ .40  
10  
11  
12  
13  
14  
xxx  
xxx  
xxx  
01303  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
xxx  
120V FOR ESP 120V . . . . . . . . . . . . . . . . . . . . . . . . . . .  
208~240V 60Hz FOR ESP 220V . . . . . . . . . . . . . . . . . . $ 183.60  
HEX SCREW M4*12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
PRESSURE RELEASE DRAIN TUBE FOR ESP 120V . . . .  
PRESSURE RELEASE DRAIN TUBE FOR ESP 220V . . . .  
GROUP JET D0.8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
GROUP FILTER ST.STEEL D13.8*d10.5*11.5 . . . . . . . . . .  
TEFLON GASKET D22*d18*2.0 . . . . . . . . . . . . . . . . . . . .  
DISTRIBUTION GROUP CAP . . . . . . . . . . . . . . . . . . . . . .  
DISTRIBUTION GROUP ASSY . . . . . . . . . . . . . . . . . . . . .  
15  
16  
17  
18  
19  
20  
21  
xxx special order contact Cecilware for more information  
19  
 
NOTES  
Cecilware Corporation 43-05 20th. Avenue, LIC NY 11105  
Tel: 800.935.2211 / 718.932.1414 Fax: 718.932.7860  
®
Since 1911  
www.cecilware.com  
20  
 

Black Box Network Hardware Black Box Feed Through CAT6A Patch Panels User Manual
Black Decker Sander MS1000 User Manual
Bose Car Amplifier SA 4 User Manual
Boss Audio Systems Car Stereo System CCR612 User Manual
Boston Acoustics Speaker SUB10F User Manual
Bowers Wilkins Speaker CCM6 User Manual
Bradford White Corp Water Heater SW 2 65 L User Manual
BRK electronic Smoke Alarm SL177 User Manual
Broan Fan QTRE080R User Manual
Butler Coffeemaker 645 082 User Manual